Ft int2

Type Function module

Input IN REAL (input signal)
K REAL (multiplier)
RUN BOOL (enable input)
RST BOOL (Reset input)
OUT_MIN REAL (lower output limit)
OUT_MAX REAL (upper output limit)
Output OUT_MAX REAL (upper output limit)
LIM BOOL (TRUE if the output is at a limit)
FT_INT2 is an integrator module which calculates internal with double-precision and ensures a resolution of 14 decimal places. This makes it suitable to use FT_INT2 unlike FT_INT, for power meters and similar applications.
For example, an input signal of 0.0001 results in a sampling time of 1 millisecond and an output value of 100000 a value of 0.0001 * 0.001 seconds = 0.000001. To be added to the baseline of 100000, which results inevitably reflect the value of 100000 because the resolution of the data type Real can only collect up to 8. FT_INT2 solves this problem by calculating internal with double-precision (14 decimal places) and adds even the smallest input values so that no information is lost.

ft_int2